We are always eager to deliver all of our products only in a proper working condition. Nevertheless small, hidden faults will not be found during all your beta tests. Only after a longer use and under different circumstances these problems can be recognized. That means, that we are very happy to get our customers reaction to improve our products.

Hotline for registered customer

We provide a telephone line, one in Switzerland (English, German and French) and one in Germany for your inquiries. In case of a short absence both lines are equipped with an answering machine.

KEY SOFT SERVICE (Germany)

Tel.

06321-95 25 24

Monday - Friday (09:00 - 12:00, 13:30 - 18:00), German only

KEY SOFT SERVICE (Switzerland)

Tel.

+41-41-922 03 14

Monday - Friday (09:00 - 12:00, 13:30 - 18:00) international

Free download area

We are offering for all interested person the demo versions of our software products as well as our detailed product informations or product pictures in a better quality.

Try these examples: (news from KN6000 coming soon)

HD-SX6 picture

Product piture in good quality (432KB, about 5 min/28.8Kb, 2 min./ISDN download)

HD-SX6 installed

Picture of installed HD-SX6

HD-SX6 English manual

The HD-SX6 owners manual as Adobe Acrobat file (673KB, about 8 min/28.8Kb, 4 min./ISDN download)


HD-AE5000 manual in English

The HD-AE5000 owners manual as Adobe Acrobat file (971KB, about 10 min/28.8Kb, 5 min./ISDN download)

HD-AE5000 installed

Picture of installed HD-AE5000

MIDI File

Intro, Demo file from Roland Wapf

to the top

Protected download area

Only registrated customers can get access to our password protected download area. All files are free for your personal use.

I m a reistered user

Service centre/distributor
(English only)

All our Update Versions are available as a self extracting *.exe file. Please refer the detail instructions for these new software.

to the top

Question and answer

Under this section we will publish the valuable and topical inquiries. For your reference, latest Q&A will be on top of the list.

NEWS: HD-SX6

Q:

Walter Ernst wrote: Dear sirs, I have download the latest software update from your web-site and installed on the KN6000. After a new "Initialize hard disk" my Quick Load function don't load the previous Song Selection list. It stays on the Menu page of HD-SX6.

A:

Since the new version is able to store your personal settings there is a new sector on the HDD which is now undefined.
If you store your personal settings (they will be written to the HDD reserved area) further HD-SX6 access will load your Save Options.


Q:

I have download the latest update from your web-site. When I now press and hold the 4 PM button during turn ON a message comes up like "PLEASE WAIT -- DEVICE= MASK ROM". Whats wrong here? I did all the steps for extracting written in your manual.

A:

This message will appear, if you haven't a correct start diskt for the Flash-Rom update.
You have more than the 4 necessary files on your disk. Go back to your computer and change to the MS-DOS window and check the physicaly order of the files and you will see there is an other file. Change to the A: drive and type dir A:\>dir
You will see the following files if the disk is correct!

TECHNICS HDD

459

27.05.99 15:39

TECHNICS.HDD

DUMMY 1

10

30.04.99 14:52

DUMMY.1

DUMMY 2

10

30.04.99 14:52

DUMMY.2

EXTAPR SLD

379'614

22.05.00 1:54

EXTAPR.SLD

Maybe you have download the *.exe file direct to your floppy disk, which is wrong in this case!

If you check the order of the disk on the Explorer, you will find another, logical order.


If I load a new bank from HD-SX6, many times I still have the Sequencer from the previous bank still play.

A:

This is happen, if you save a composer bank without a sequencer file, the previous loadet sequencer will stay in the memory as long as you overwrite it with a new one or an empty one. Therefor we recommend to save always an empty sequencer with your data file. Just use our File Save Option as proposed.


Q:

The loading speed of my HD-SX6 is very slow, about 6-7 seconds! My previous HD-AE5000 was much quicker!

A:

On the latest version (12/04/2000/C you will get a much better acces time, even if the files are big. Just download the latest version and try.

 
Q:

I sometime recogize that files are not loaded correctly from HDD. I m using all my KN2000 files which was working very well on the HD-MEC2000.

A:

Unfortunately we found out that the actual version of HD-SX6 don't initialize some parameter of the sound memory.
This circumstanceis only nown from KN2000 files with Sound Memory. For immediate help, please press an other sound group button and the Memory buton again to initialize the memory content.
We already test a new version with an improvement for that problem. Please look for the new mid May version.

 
Q:

Reserved for your question

 
A:

Reserved for our answer

 

Q & A: HD-AE5000

to the top

Q:

If I want to store my MIDI settings to the hard disk, unfortunately these settings won't be loaded from hard disk!

A:

The KN5000 knows the option "load MIDI settings from File" in the MIDI menu. If this be switch "NO", (initial hardware setting) the MIDI settings cannot be loaded. Change that switch to "YES" and you will find your MIDI settings also loaded from HD-AE5000.


Q:

Why will no GM identification be sent to the MIDI equipment during load from the hard disk, like it is the case from the floppy disk?

A:

Already with our first hard disk extension (HD-MEC2000) musicians have pointed out, that the GM identification from the hard disk should not be sent to the MIDI equipment trough MIDI OUT.
If your MIDI system contains more than only one keyboard, the individual settings will be changed with each load of a GM files and will set your adjustments to the GM standard.


Q:

Can the parallel port cable and software of HD-TechEditor96 also be used for HD-AE5000?

A:

The transfer protocol was extended from the 4-bit nibble mode to the topical 8-bit bi-directional mode because of the much bigger amount of data's. Therefor the software need to developed completely new (32bit) and also a new parallel port cable is necessary. The special cable fulfills the extended CE-norms.


Q:

The save and load operation of a title with a CUSTOM file take always a long time, up to 1 minute.

A:

Since the CUSTOM area is built up with Flash-ROM's and a save function to this semiconductor takes about 1-2 seconds per place (Custom file can store up to 20 places) the load/save operation with the Custom option need some more time. The basic hard disk access to such a custom file is only about 3-4 seconds but the Flash-ROM operation need the long time.

 

Q & A: HD-TechManager5000

to the top

Q:

Nothing happens if I press start button in the PC-LINK page.

A:

Without the pport Update which is included in the HD-TechManager5000 you are not able to activate a communication to your PC. With the HD-TM Update you will find all transfer messages on the PC-Link page.


Q:

I have version 1.3 of the HD-TechManager5000 on my computer. When I try to upgrade using your new disc, the Set up manager searches for a previous intallation and then askes me to select the directory with the previous version of the HD-TechManager program. In my case this is C:\program files\HD-Techmanager 5000. The response then is that I have not selected the correct path and the upgrade will not install. This is not your fault!

A:

Yes it is! Since we added a blank on the international version of HD-TM5000 1.3 in the file name of HD-TechManger 5000.exe your upgrade program can't find the HD-TechManager5000. exe file. With the explorer, you simply rename your HD-TechManager5000.exe file to HD-TechManager 5000.exe (space between r and 5) and also your upgrade will work. That's all and .......... sorry!